Unit installation

Smart Output Module
Page 14
8.4 Adjust the Pulse Length
The modules appear in the locking plan as the locking type "expansion module". You
can select a pulse length from 0.1 to 25.5 seconds in the configuration for each
module. This length then applies to all of the module's outputs.
8.5 Select Signaling
Signaling is a special function where two of a module's outputs always work together.
The first output reacts completely normally, depending on transponder operation; the
output assigned to it simultaneously generates an alternating signal. You can select
this option, for example, if you want to have the keys that are released when an
elevator is controlled blink.
Attention: If you select this option, the number of outputs that are switched
when authorized is reduced from eight to four.
Output assignments for signaling:
1 Æ 5
2 Æ 6
3 Æ 7
4 Æ 8
8.6 Automatic Name Assignment in the Software
The SimonsVoss software automatically assigns designation to modules when the
modules are created. The following convention is used:
SMART RELAY NAME - MOD0 - OUT1
(z.B. Aufzug1-MOD0-OUT4)
8.7 Inverting the Outputs
This option allows the output switching behavior to be inverted. If there is no supply
voltage, all output relays are always closed.
Module
address:
0 to F
Output
number:
1 to 8