Unit installation

Smart Output Module
Page 6
4.0 Before Installation
Unpack the Smart Output Module and inspect it for external damages.
Connect the Smart Output Module to a type SREL.ADV Smart Relay (see
Connection to the Smart Relay) and provide both units with voltage over the
power supply.
Note the polarity.
Activate the Smart Relay with a transponder in the condition as received from
the factory. This activates all Smart Output Module outputs, which is shown by
all LED’s on the Smart Output Module lighting (green).
5.0 Installation
Cut the DIN rails to size and tighten the screws.
Switch off the supply voltage.
Mount the units on the DIN rail (latch).
Connect all cables (see Terminal Assignments and Connection Examples).
Be sure to pay attention to the polarity when connecting the supply voltage.
Switch on the supply voltage.
Program the Smart Relay and the Smart Output Module with the SimonsVoss
software (see Programming and Configuration).
Then test the function with authorised transponders.