Unit installation
VdS Shunt lock function 3066
Page 27
7. You can also optionally use an activation unit without antenna extender.
Install it as described in Chapter 4.2.
In order to guarantee that the system can be
externally activated from the
outside only, you must then install a
button in the outside area. You cannot
externally activate or deactivate the system by operating a transponder until
this button is pushed.
The deactivation acknowledgement input (pin 13) is suppressed on master
activation units (MAs) as long as it is connected to ground (normally closed
button in outside area).
A Schottky diode decouples the deactivation acknowledgement line (see
below). This diode is needed, however, only if there are slave activation units.
With slave activation units (SAs), you can apply the activation suppression
(pin 12) to ground over a normally-closed button that is in the outside area. If
there is also an activation suppression button on the master, you should use a
circuit according to the figure below.
Schottky diode
1N5817
Electric strike in
outside area
Pin 13 12 Pin 13 Pin 12
Pin 13 Pin 13 Pin 13
Pin 14 Pin 14 Pins 5,7 Pin 14 Pin 14 Pin 14
Pin 14
Activation re
q
uest
Deactivation
r
e
q
uest
Deactivation
DA DA DA
MA SA
SA
BAC
Electric
strike in
outside
area