Unit installation

VdS Shunt lock function 3066
Page 19
After you have completed the installation work, carry out a function test.
Do this by operating an authorized transponder near the activation unit twice in quick
succession. The light emitting diodes on the activation unit and the deactivation
unit(s) go out and you receive the acoustic acknowledgement signal from the BAC or
(if jumper B1 is inserted on the right) the signal lasting 2.5 seconds from the activation
unit indicating that the alarm system has been activated.
Check whether the cylinder(s) or Smart Relay(s) have been deactivated.
Operate the transponder near the activation unit two times again. This unit signals the
activation of the lockings only visually on the LED with 1 x short-long blinking or
(if jumper B1 is inserted on the right) with a double signal tone from the activation
unit. The LEDs on the shunt lock components light again.
The locking cylinder or Smart Relay is now active and can be switched if you operate
an authorized transponder one time.
Please set the acoustic activation acknowledgement to BAC operation (insert jumper
B1 on the left) if you have not done this yet.
Test the Shunt lock function several times.