Unit installation
VdS Shunt lock function 3066
Page 6
Time zone control und access logging
The activation units (master and slaves) can log activation/deactivation switches
(access logging), and you can define time slots during which it is possible to
activate/deactivate the system (time zone control):
Access logging The activation unit stores the last 128 activations/deactivations
with date, time and the user name of the transponder. You can
read out the data with the programming device or over the
network.
Time zone control You can program activation units in such a way that
authorized transponders can only switch the alarm system at
certain times.
Refer to the Software Operating Instructions, timezone admiinistration
1.2 Safety Remarks
Read through the assembly instructions carefully and thoroughly before installing
and commissioning the Shunt lock components. They contain important
information on the assembly, programming and operation.
The components are built in accordance with the latest state of the technology.
Use them only as instructed and when they are in perfect technical condition and
are properly installed according to the technical specifications
The manufacturer is not liable for damages that are caused by use that does not
comply with the directions.
Keep the documentation that comes with the product and system-specific notices
in a safe place.
Only trained experts are authorized to perform installation, programming and
repair work.
Soldering and connection work anywhere in the entire system must be performed
only when the system is voltage-free.
Soldering work must be performed with a temperature-controlled soldering iron
that is electrically insulated from the power system.
Observe VDE safety regulations and regulations from the local electric utility.
Do not use the components in areas subject to explosion hazards or in areas with
fumes that dissolve metal or plastic.
DIN norms and the guidelines of VdS Class C must be adhered to.