Unit installation

VdS Shunt lock function 3066
Page 5
Switching on the alarm system (burglar alarm system, BAS)
The person with switching authorization presses his or her transponder near an
activation unit two times in quick succession (within 2 sec.). This sends a signal to all
deactivation units present. If lock contacts are connected to the deactivation units, the
DAs first verifies that the doors have been correctly locked. The digital locking
cylinders or Smart Relays are not deactivated unless this is the case, so that it is no
longer possible to enter the secured area. The activation unit does not receive a
positive acknowledgement until all
lockings have been successfully deactivated. It
then uses a floating contact to activate the alarm system externally (compelled
signaling). The light emitting diodes of the activation units signal this by lighting for 2.5
seconds. The light emitting diode(s) on the deactivation unit(s) go out. The BAS
acoustically signals – for example, on the activation unit – that the system has been
successfully activated.
Switching off the alarm system
The person with switching authorization again presses his or her transponder twice in
quick succession within transmitting range of the activation unit. The deactivation
units signal this to the digital locking cylinders or the digital Smart Relays. The LEDs
on the activation units visually signal that the system has been successfully
deactivated by blinking 1x short-long. The LEDs on the deactivation unit(s) light
again. (The LEDs on the deactivation units are used only for testing purposes, so they
do not have to be brought out where they can be seen). Now it is possible to access
the doors again with all authorized transponders.
By simply clicking the transponder button within transmitting range of
activation units, you can determine the activation state of the alarm system if
the LEDs on the activation units are brought out where they can be seen. 1 x
short-long blinking means "deactivated", 1 x long (2.5 sec.) blinking means
"activated".
Activation transponder
For emergencies, you can use the locking plan software to program a transponder
that cancels the deactivation of the locking cylinder so that the doors can be opened
with an authorized transponder. However the alarm system remains activated
externally.