Unit installation

Digital Locking Cylinder 3061 VdS
Page 5
3.3 Logging Unauthorised Access Attempts
For cylinder version 10.2 and later and in combination with the LDG Version 1.40, it is
possible to log unauthorised access attempts, as well as authorised accesses. This
includes both access attempts without authorisation and access attempts outside the
specified time zone. In this connection, however, only transponders from the locking
system are logged, which means that the transponder must have the same locking
system ID (SID).
3.4 No Acoustic Programmer Acknowledge
When programming over the network, it can be advantageous to deactivate the
acoustic programmer acknowledge. You can do that with this function.
4.0 Battery Warnings
4.1 Locking Cylinder
Warning level 1 for main battery
If the main battery of the locking cylinder goes empty, eight short signal tones, coming
quickly one after another, sound after you operate the transponder and before the
cylinder couples. You must replace both batteries now.
Warning level 2 for backup battery (SW Version 10.0 & SW Version 10.1)
In addition to the main battery warning, an additional eight short signal tones, coming
quickly one after another, now sound for the backup battery warning. The cylinder
does not couple until after the signals. From now on, the backup battery is active. You
must replace both batteries as soon as possible.
Warning level 2 for backup battery (SW Version 10.2 and later)
Now the signal tones of the backup battery warning sound for only approximately 30
seconds (without the main battery warning). The cylinder does not couple until after
the signals. From now on, the backup battery is active. You must replace both
batteries as soon as possible.
Warning level 3 (SW Version 10.2 and later)
If you continue to ignore this backup battery warning, either the door can be used 50
more times or the cylinder switches off after 4-5 weeks if there is no further operation.
In both cases, the cylinder switches into the so-called storage mode. After this, you
can only open the cylinder with the programming device.