Unit installation
VdS Shunt lock function 3066
Page 4
2.0 Shunt lock function 3066 Operation
Switching on the alarm system (burglar alarm system, BAS)
The person with switching authorization presses his or her transponder two times in
quick succession (within 2 sec.) near an activation unit. This sends a signal to all
deactivation units present. If lock contacts are connected to the deactivation units, the
DAs first check whether the doors have been correctly locked. The digital locking
cylinders or Smart Relays are not deactivated unless this is the case, so that it is
no longer possible to enter the secured area. The activation unit does not receive a
positive acknowledge until all
lockings have been successfully deactivated. It then
uses a floating contact to activate the alarm system externally (compelled signaling).
The light emitting diodes on the activation units signal this by lighting for 2.5 seconds.
The light emitting diode(s) of the deactivation unit(s) go out. The BAS acoustically
shows that the activation has occurred - for example, on the activation unit.
Switching off the alarm system
The person with switching authorization again presses his or her transponder twice in
quick succession within the transmitting range of the activation unit. The deactivation
units signal this to the digital locking cylinders or digital Smart Relays. The BAS
acoustically signals the successful deactivation. The LEDs on the activation units
signal that the activation has occurred by blinking 1 x short-long. The LEDs on the
deactivation unit(s) light again. (The LEDs on the deactivation units are used only for
testing purposes, so they do not have to be brought out). Now it is possible to access
the doors again with all authorized transponders.
☺ In network operation, (not VdS), you can do without deactivation units. In this
case, the network nodes take care of activating and deactivating the locking.
☺ By simply clicking the transponder button within the transmitting range of
activation units, you can determine the activation state of the alarm system if
the LEDs on the activation units are brought out.
1 x short-long blinking means "deactivated"
1 x long (2.5 sec.) blinking means "activated"
Activation transponder
For emergencies, you can use the locking plan software to program a transponder
that cancels the deactivation of the locking cylinder so that the doors can be opened
with an authorized transponder. The alarm system, however, remains activated
externally and the alarm will be triggered.