WaveNet Radio Network 3065
Page 19
9.0 Battery warning
If the voltage of the battery used to supply the Lock Node drops below a certain level,
this can cause communication problems between the Lock Node and its associated
lock, and also between the Lock Node and a Router Node (WaveNet Repeater Node,
WaveNet Router Node, WaveNet Central Node).
If this type of fault occurs, then the āNā behind the lock concerned is shown in red
(communication fault). If after repeated recording the red N does not disappear, then
you should check whether the battery requires replacement.
9.1. Changing the Lock Node batteries
To change the batteries of a Lock Node, remove the node from its place of installation
(e.g. flush-type box) and remove the cover on the back.
The position of each battery is clearly marked in the battery compartment. You should
only use batteries approved by SimonsVoss.
Please watch the LED when inserting the new battery. It should flash (2 times) briefly
immediately after you have placed the first
new battery into the empty battery
compartment. The node is then ready for operation (power-up reset). If the LED does
not light up, please take out the battery, short-circuit the battery contacts in the Lock
Node, then replace the battery.