Unit installation

WaveNet Radio Network 3065
Page 13
In order to make installation as easy as possible, the casing of the WaveNet Lock
Node is designed to fit into a standard flush-type box (40 mm deep,
58 mm Ø) in accordance with DIN 49073 Part 1 (for installation in a light switch strip,
for example).
Note: Some ranges of switch have less space because of the way the cover is
attached.
However, you should ensure that there is no excessive interference in or around the
light switch strip – insufficiently suppressed ballasts and so on. In extreme cases you
may have to fit an additional flush-type box further away in order to house the Lock
Node.
Lock Node with casing
Lock Node inputs / output
Every WaveNet Lock Node has one output and three inputs (for door monitoring, for
example).
The three inputs enable up to three external floating contacts to be connected.
This enables the central monitoring of devices such as door and lock contacts as well
as motion sensors, light barriers and so on – via the WaveNet network.
The status of each connected contact can be polled by the central computer at any
time, and changes to the contacts (events) can (if the Lock Node is configured
accordingly) also be automatically registered by the central computer.