SMART RELAIS 2 3063 SREL, SREL.ZK, SREL.
SMART RELAY SREL, SREL.ZK, SREL.ADV 1.0 IMPORTANT INSTRUCTIONS .......................................................4 2.0 PRODUCT DESCRIPTION .............................................................4 3.0 BEFORE PLACING AN ORDER ....................................................5 4.0 3.1 You need to establish which version of Smart Relay is required ... 5 3.2 You need to establish what accessories are required ..................... 5 3.3 Mains adaptors need to be planned and acquired ..
SMART RELAY SREL, SREL.ZK, SREL.ADV 7.7.8 Limited range ..................................................................................... 16 7.7.9 External beeper/ External LED ......................................................... 16 7.7.10 Logging unauthorised attempted access events ........................... 18 8.0 9.0 SUMMARY OF DIODE SIGNALS ................................................18 8.0 Description of functions ...................................................................
SMART RELAY SREL, SREL.ZK, SREL.ADV 1.0 Important instructions Safety Instruction: Warning: – The batteries used in this product may pose a fire or burn hazard if handled incorrectly. Do not recharge, open or burn these batteries, or heat them to over 100°C. Specialist knowledge in door mechanics, door approvals, electronic system installation and the use of SimonsVoss software is required when installing a SimonsVoss Smart Relay. This is why only trained specialists may install Smart Relay.
SMART RELAY SREL, SREL.ZK, SREL.ADV 3.0 Before placing an order 3.1 YOU NEED TO ESTABLISH WHICH VERSION OF SMART RELAY IS REQUIRED Smart Relay Basic version: Order code: SREL This relay provides a simple yes/no authorisation for a maximum of 8,184 different transponders. Smart Relay Plus version with access event logging and time zones: Order code: SREL.ZK Similar to the basic version, but with the option of separately connectable access event logging for the last 1,024 accesses (firmware version 4.
SMART RELAY SREL, SREL.ZK, SREL.ADV Warning! Do not use switching power supplies near Smart Relays. All mains adaptors are to be provided by the customer; they cannot be acquired from SimonsVoss. 3.4 YOU NEED TO DETERMINE THE INSTALLATION LOCATION The transponder transmission range for Smart Relay (read range) is a max. of 1.5 m, but may be reduced in metallic environments, particularly in magnetic fields or where there is aluminium.
SMART RELAY SREL, SREL.ZK, SREL.ADV INSTALLATION OF BACKUP BATTERY Backup Batterie einsetzen, das Smart mit Only use thenur backup battery ifwenn the Smart Relay isRelais powered use this battery if the Smart via a mains adapter. Do not Netzteil betrieben wird, bei Betrieb mit SREL.BAT diese Relay is powered by SREL.BAT. Batterie nicht einsetzen! SREL und SREL.ZK +/~ -/~ C A B +V F3 F2 F1 SREL.
SMART RELAY SREL, SREL.ZK, SREL.ADV 5.0 Installation Switch off the power supply (disconnect the plug or battery if necessary). Connect all cables to their designated terminals on the Smart Relay (see Terminal Assignment on the next page). It is essential to ensure the polarity is correct if you connect a DC mains adapter. You will achieve the largest reader range possible if the Smart Relay antennas are aligned in parallel to that of the transponder.
SMART RELAY SREL, SREL.ZK, SREL.ADV 6.0 Terminal Assignment 6.1 SREL AND SREL.ZK Power supply Netzteil { +- // ~~ Battery SREL.BAT Batterie SREL.BAT Relais Relay SREL.ADV Externe EinExternal inputs und and outputs Ausgänge 1 RS 485-COM 2 RS 485-A 3 RS 485-B 4 + Vaux (3...5 V) 5 LED / Buzzer / Input 1 / CLS 6 Seriell 1 / Input 2 7 Seriell 2 6.2 { NC COM NO +/~ Power supply Netzteil { -/~ Batterie SREL.BAT Battery SREL.
SMART RELAY SREL, SREL.ZK, SREL.ADV 6.3 DESCRIPTIONS OF CONNECTIONS IN SREL, SREL.
SMART RELAY SREL, SREL.ZK, SREL.ADV 7.0 Programming and configuration If Smart Relay is selected as the lock type in the SimonsVoss software (LDB Version 1.40 or higher, or LSM 2.
SMART RELAY SREL, SREL.ZK, SREL.ADV 7.1 ACCESS CONTROL Only possible in SREL.ZK und SREL.ADV versions. The 1,024 most recent transponder transactions are logged with the date and time. 7.2 TIME ZONE CONTROL Only possible in SREL.ZK und SREL.ADV versions. A time zone plan can be uploaded and the transponders are approved or blocked according to their time zone group. 7.3 OVERLAY Replacement transponders can overwrite their corresponding original transponders.
SMART RELAY SREL, SREL.ZK, SREL.ADV If you select time switchover, the following options are available to you in the 'Timecontrolled switchover' box (several options can be selected): 1. Manual lock The door does not lock automatically after the pre-set point in time until an authorised transponder makes a booking after this time. 2. Automatic lock (basic setting) The door is locked precisely at the point in time specified in the time zone plan. 3.
SMART RELAY SREL, SREL.ZK, SREL.ADV 7.7.1 SMART RELAY IN OMRON MODE Authorised? Access control system ExExternal ternes Zutrittskontrolloder access control or time-andZeiterfassungssystem attendance system GND Freischalt Relais Relay release + 5..12VDC 1K 1K 1K PuPull ll Upup Widerstände resistances CLS Clock / D1 Data / D0 Netzteil { +- // ~~ F3 F2 F1 Batterie SREL.BAT Relais { NC COM NO Brown White Green Grey Yellow } Externe ExternalAntenne antenna SREL.AV SREL..
SMART RELAY SREL, SREL.ZK, SREL.ADV 7.7.2 NO AUDIBLE PROGRAMMING ACKNOWLEDGEMENT SIGNALS SREL.ADV only You should check this field if you do not want audible programming acknowledgement signals to be emitted from a connected buzzer or beeper while you are programming Smart Relay. 7.7.3 EXTERNAL LED / EXTERNAL BEEPER SREL.ADV only This indicates which external component group is connected.
SMART RELAY SREL, SREL.ZK, SREL.ADV 7.7.7 INTERFACE For SREL.ADV only You can enter the type of card reader here which the Smart Relay is to simulate for operation as a serial interface. The following options are available: • Wiegand, 33 bit • Wiegand, 26 bit • Primion • Siemens • Kaba Benzing • Gantner Legic • Isgus You can find the relevant information on cabling in the section "Smart Relay as a serial interface." 7.7.
SMART RELAY SREL, SREL.ZK, SREL.ADV Evtl. Widerstand zur Poss. resistance to power Leistungsbegrenzun limitation. The V+ output g. Dermax. Ausgang V+atliefert supplies 10 mA max. 10 mA bei 3VDC 3 V DC Entweder Buzzer oder LED Either buzzer or LED +/~ Netzteil { -/~ Brown White Green Grey Yellow V+ F3 Batterie SREL.BAT Relais { } External Antenne antenna Externe SREL..AV SREL.
SMART RELAY SREL, SREL.ZK, SREL.ADV 7.7.10 LOGGING UNAUTHORISED ATTEMPTED ACCESS EVENTS Only for SREL.ZK und SREL.ADV Normally, only authorised transponder operations are logged. If you also wish to record an attempt to open the door with a non-authorised transponder, you need to select this option. 8.0 Summary of diode signals 8.
SMART RELAY SREL, SREL.ZK, SREL.ADV 8.1 WIEGAND INTERFACE (33 BIT AND 26 BIT) Externes Zutrittskontrolloder External access control or timeand attendance-system Zeiterfassungssystem GND + 5..12VDC 1K 1K 1K Pull Pull Up up Widerstände resistances CLS D1 D0 Netzteil { +- // ~~ F2 F1 Batterie SREL.BAT Relais { NC COM NO Brown White Green Grey Yellow } EExternal xterne antenna Antenne SREL..AV SREL.
SMART RELAY SREL, SREL.ZK, SREL.ADV 8.2 KABA BENZING, SIEMENS, GANTNER LEGIC, PRIMION, ISGUS INTERFACE Externes Zutrittskontroll- oder External access control or timeand Zeiterfassungssystem attendance-system GND + 5..12VDC 1K 1K 1K Pull Up Widerstände Pull up resistances CLS Clock Data +/~ Netzteil { -/~ F2 F1 Batterie SREL.BAT Relais { NC COM NO Brown White Green Grey Yellow } EExternal xterne Antenne antenna SSREL..AV REL.
SMART RELAY SREL, SREL.ZK, SREL.ADV 9.0 Maintenance 9.1 BATTERY WARNING AND BATTERY REPLACEMENT WHEN THE BATTERY SREL.BAT IS USED A Smart Relay can emit a battery warning as follows when the battery capacity is depleted: SREL, SREL.ZK, SREL.ADV Inside LED flashes 8x each time a transponder is used and before the relay switches. This LED should be visible from the outside in the case of battery-powered operation. SREL.
SMART RELAY SREL, SREL.ZK, SREL.ADV 10.0 Technical data for SREL Housing made of black plastic: dimensions l x w x h 72 x 57 x 25.5 mm Protection rating IP20, not tested for outside use Temperature When operating: -22ºC to 55ºC In storage: 0ºC to 40ºC Humidity < 95% without condensation Circuit board dimensions l x w x h 50 x 50 x 14 mm Mains voltage 12 V AC or 5-24 V DC (no reverse polarity protection) Power limitation Mains adapter must be limited to 15 VA Standby current < 5 mA Max.
SMART RELAY SREL, SREL.ZK, SREL.ADV 11.0 Smart Relay 2 11.1 SMART RELAY 2 VERSIONS SREL2.G2.W: The SREL2 is basically used with transponders, i.e. as purely "active" components. There is also the option of using a Compact Reader and operating the SREL with Mifare Classic/DERFire® cards. This relay provides a simple yes/no authorisation for a maximum of 64,000 different transponders. SREL2.G2.W.WP: As described above, but with a waterproof design.
SMART RELAY SREL, SREL.ZK, SREL.ADV Use of the backup battery (CR1220 Sony) is described in Section 4.1. 11.2 CARD READER VERSIONS IN CONJUNCTION WITH SREL2 The SC components can be operated with Mifare Classic® or Mifare DESFire®. SC.M.E.G2.W: Smart Card Mifare External (external card reader) G2 (Generation 2) W (white housing) A maximum of two external card readers (SC.M.E.G2.W) and one internal card reader (SC.M.I.G2) can be connected to an SREL2.ZK.MH.G2.W or SREL2.ZK.MH.G2.W.WP.
SMART RELAY SREL, SREL.ZK, SREL.ADV 12.0 Description of the SREL2 connections Name Symbol Description Mains adapter Mains adapter Battery Relay COM + DC - DC NO relay External antennas Brown White Green Grey Yellow Functions connection BN WH GN GY YL F1 F2 F3 SVB Direct current 9 to 24 V DC Direct current 9 to 24 V DC CR1220, Sony – Backup battery Common contact in the relay. This contact is wired against NO relay (closing contact) Normally open contact in the relay.
SMART RELAY SREL, SREL.ZK, SREL.ADV 13.0 Technical data for SREL2 Housing made of white plastic: dimensions l x w x h Semi-transparent base plate Protection rating Temperature Humidity Circuit board dimensions l x w x h Mains voltage Power limitation Standby current Max.
SMART RELAY SREL, SREL.ZK, SREL.
SMART RELAY SREL, SREL.ZK, SREL.ADV 14.0 PRODUCT DESCRIPTION 14.1 ORDER CODE WN.CN.UR.SCHALT, referred to as INPUT NODE below. 1.2 HIGHER-RANKING LOCKING LEVEL The text field placed under Level 2 automatically receives the "standard" template. The text is indented 1.25 cm. 15.0 WARNING 2.1 SAFETY − Specialist knowledge in access control systems, door mechanics, door approvals, electronic system installation and the use of SimonsVoss software is required when installing a SimonsVoss INPUT NODE.