Operating instructions
Manual – LDB 1.5
Page 97
97
11.4 Performing emergency opening
If there is no authorized transponder available, you can perform an emergency
opening using the Configuration tool and your password. To do this, choose
Programming > Emergency Unlock.
Enter your password for the Lock System and click Unlock.
The password for a lock that has not been programmed is 0x0 (zero, lower-
case x, zero). Please note that locks cannot be emergency-unlocked in
Storage Mode.
If the data you enter is not accepted, check your password, making sure you
enter the correct upper and lower case letters.
11.5 Setting the time
If the time recorded by a lock is not the same as the actual time, you can reset it.
You should reset the time in the locks at least once a year in order to
guarantee accurate times. The holiday list for the next 127 weeks is also
regenerated.
Approve the Lock System using the password. Click the lock concerned so that it is
highlighted. Choose Programming > Set clock in lock. You can then change the
Lock System and/or lock in the window which opens. Position the Configuration tool
in front of the lock, and then click OK.
The computer’s time is always used, so you should check to make sure its
date and time are correct.