The time an elevator button is lit can be set as the pulse length of the Output Module
concerned, whereas the flashing frequency of authorized buttons is fixed.
If the outputs are connected correctly, then the floor buttons will flash to show the
user which floors are allowed for access using his transponder. If, within the
predefined time, he presses a floor button to select a floor, then that button will light
up without flashing to show the chosen floor.
The number of usable outputs per Output Module drops from 8 to 4 when
used this way; outputs 1–4 respond to the transponder and outputs 5–8
perform the function of a flasher relay.
Outputs 1 & 5, 2 & 6, 3 & 7 and 4 & 8 are permanently assigned to one
another in signalling mode.
The signalling mode and the pulse length always apply to the whole Module.
If authorized, users can also select more than one floor.
The signalling mode is indicated by the last four outputs of each Module having new
names in the Lock System (i.e. Elevator main building_Mod#0_Out#5_Sig#1