Operating instructions

Manual – LDB 1.5
Page 54
54
4.13.3 No acoustic programming confirmations
If you do not want the connected buzzer / beeper to respond when the SmartRelay is
programmed, then check this box.
4.14 Replace control unit with SmartRelay
If you need to replace a control unit with a SmartRelay, then observe the
following:
1. Reset the current status of the lock in the Lock System (see Chapter 8 of the
Software Manual).
2. Change the type from control unit to SmartRelay.
3. Reprogram the SmartRelay.
4. Adjust the configuration if necessary.
It is generally not possible to program locks that differ in terms of hardware and
software.
4.15 SmartOutput Modules (SOM) – Extension modules
Setting up SmartOutput Modules
If SmartOutput Modules are to be used in your Lock System (for controlling an
elevator, for example), then you will have to create a new lock in the software and
define it as a SmartRelay, since the Modules can only be run in conjunction with a
SmartRelay Advanced.