If you would like the SmartRelay to transmit transponder data to a non-SimonsVoss
system and upon authorization from that system open a lock, then select this option
for both the SmartRelay and the lock.
Define the type of external system under ‘Interfaces’.
4.12 Advanced Properties
SimonsVoss in the United States primarily sells the Advanced version
(SREL.ADV) of the SmartRelay. If you make arrangements to purchase the
Standard version (SREL) this feature is not included.
4.12.1 Digital SmartRelay – Pulse length
This is where you specify the length of the switching pulse, in seconds. This figure
can be between 0.1 and 25.5 seconds. If you enter 3 seconds, for instance, then a
door opener will be released for three seconds before locking again.
4.12.2 Digital SmartRelay – Time switching
When time switching is active, a time zone plan must be loaded which enables the
general authorization of the SmartRelay during the times marked (in Group 5). For
example, a door can be left unlocked for everyone during the day, but can only be
opened with a transponder during the night.
Warning: With installations of this type, ensure that the power supply and
door openers are also suitable for continuous current operation.
If time switching is selected, the following options will be activated in the Time-
controlled relay switching area (multiple selections possible):
Manual lock
The door is not automatically locked at the defined time, but only when it records
an authorized transponder after that time.
Automatic lock (default setting)
The door is locked at the time defined in the time zone plan.
Manual unlock (default setting)
The door is not automatically unlocked after the defined time, but only when it
records an authorized transponder after that time.
Automatic unlock
The door is unlocked at the time defined in the time zone plan regardless of any
transponder activity.
Transponder active
Only when locked (default setting)
In this mode, the transponder has no effect during the unlocked period.
Always