Operating instructions

Manual – LDB 1.5
Page 124
124
Check the Successful list carefully. If, even though the System has already been
programmed, an ‘unknown lock appears there, you can assume that it has either not
been programmed yet, or that the lock has already been programmed in a different
Lock System. If a network node appears in the Errors list, then there is a problem in
the radio transmission between the Lock Node and the lock. Either the door is open,
or the distance between the lock and the node is too great.
Intermediate step if the Lock System is not yet programmed:
Mark the lock that you have networked. Choose Options > Network setup and then
click the Configure Network Nodes button.
Enter the Group and Member ID of the associated network node, and click the
Manual configuration button.
You will be asked if it is the right lock. If it is not, then select the right one. Confirm
with OK.
Repeat these steps for the other network nodes. You can now program and retrieve
data from the locks.
A blue N appears to symbolize every networked lock in the Lock Plan. If the color of
this symbol changes, then there is a fault: