Unit installation

MANUAL - BIOMETRIC READER Q3008
Page 14
14
7.0 Querying the number of learned fingerprints
You can query the number of learned fingerprints / transponder IDs at any time.
Please proceed as follows:
1. Open the locking plan with the SimonsVoss software.
2. Export the locking plan (pocket PC).
3. Bring the SmartCD into the communication range of the biometric reader.
4. Select the ‘Read‘ function.
5. Select the ‘Modify trans.‘ function.
6. Select the ‘Execute‘ function.
7. You will see a list of all users. Approved biometric reader users are indicated by
a thick black cross.
8.0 Deleting an individual fingerprint
Do not undertake any programming after a battery warning. Replace the battery
before proceeding. Refer to chapter 15.0 Replacing the battery.
To delete an individual fingerprint, proceed as follows:
1. Open the locking plan with the SimonsVoss software.
2. Remove the cross indicating authorisation from the locking plan by clicking on it.
3. Export the locking plan (pocket PC).
4. Bring the SmartCD into the communication range of the biometric reader.
5. Select the ‘Read‘ function.
6. Select the ‘Modify trans.‘ task.
7. Select the ‘Execute‘ function.
8. Select the relevant transponder.
9. Select the ‘Program.‘ function.
10. Following successful programming, the SmartLSM will display the message
“Programming successful“ and a green dot.
11. Re-import the locking plan.
The fingerprint and transponder ID have now been deleted from the biometric reader.