Unit installation
MANUAL - BIOMETRIC READER Q3008
Page 9
9
3.0 Programming
The following chapters describe the programming process in detail. If you are using
the biometric reader in a small-scale locking system, please refer to chapter 11.0
Master finger mode.
Do not undertake any programming after a battery warning. Replace the battery
before proceeding. Refer to chapter 15.0 Replacing the battery.
3.1 Commissioning
Please note:
The 3008 biometric reader must be created in the locking plan as a lock
(biometric reader) and users as transponder type biometric reader users. Users
(transponder IDs) and fingerprints can only be learned in situ with the SmartLSM and
the SmartCD.
Please proceed as follows:
1. Create a locking plan in the SimonsVoss software.
2. Create ‘biometric reader’ as a lock
Æ
biometric reader.
3. Create lock (e.g. locking cylinder).
4. Create transponder using the option Biometric reader user.
5. Issue authorisation for the ‘biometric reader’ and the corresponding lock.
6. Connect the SmartCD to the PC and bring within communication range of the
‘biometric reader’.
7. Highlight the biometric reader and launch ‘Programming Æ Lock’ in the
programming software. This is where you undertake basic configuration of the
biometric reader.
8. Once the reader has been successfully programmed, this is indicated by a pop-
up window. This time, the yellow programming lightning symbol remains
displayed in the locking plan.
9. Bring the SmartCD into the communication range of the lock to be addressed.
10. Highlight the lock to be addressed by the biometric reader and launch
‘Programming Æ Lock‘ in the programming software. This is where you
undertake basic configuration of the lock.
11. Once the lock has been successfully programmed, this is indicated by a pop-up
window.
The following programming steps are performed in situ with a PDA and
SmartLSM:
12. Export the complete locking plan (pocket PC).
13. Bring the SmartCD into the communication range of the biometric reader.