Unit installation
Q3007 Biometric Transponder
Page 11
To enter Transparent mode, please proceed as follows:
1. Press and hold the transponder button (longer than 1.5 seconds, < 3 sec.). The
LED will flash green rapidly. The Transponder will now react to the button as if it
were in Recognise mode.
2. Drag finger across sensor (LED shows green if the fingerprint is recognised).
3. The Biometric Transponder is triggered and switches to Transparent mode. The
LED flashes red.
4. Pressing the button triggers the system and the LED shows green, followed by
red flashing.
After 5 minutes, the Transponder switches off Transparent mode and returns to
Standby.
Transparent mode can also be switched off manually by pressing the Transponder
button before automatic switch-off until the green LED goes out (approx. 1.5 sec).
5.0 Programming the Transponder with the SimonsVoss software
The "Set validity" function and the "Quasi-proximity mode" are not
available for the
Q3007.
6.0 Changing the Batteries
To replace the batteries, push the battery cover downwards and remove. Take out all
the batteries and replace with new ones. Make sure that the polarity is correct
(stamped into the base of the battery compartment).