Unit installation

WAVENET RADIO NETWORK 3065
Page 21
7.9 LockNodes
WaveNet LockNodes represent the interface between WaveNet and the locks in the
digital locking and organisation system 3060 (e.g. locking cylinders, Smart Relays
etc.).
They always have:
a special B-field interface which enables communication with SimonsVoss locks
(e.g. locking cylinders, control units/Smart Relays, furniture locks, etc.)
a radio interface (868 MHz) to ensure data transmission to the WaveNet nodes
(e.g. WaveNet router nodes, WaveNet repeater nodes or WaveNet central
nodes) or
an RS485 interface and connection for an external power supply, for operation in
a ‘wired WaveNet’ (WN.LN.C)
WaveNet LockNodes can always be assigned to just one digital lock in the system
(e.g. a locking cylinder, Smart Relay or furniture lock, etc.). The distance between the
WaveNet LockNode and a digital cylinder / furniture lock must be no more than 30
cm. A minimum distance of 40 cm must be maintained between the LockNode and a
Smart Relay. We recommend fitting a cable connection between both components
with WN.KAB.WIRED-BF. In this scenario, no minimum gap needs to be observed
(with SREL.ADV only).
In a radio network, WaveNet LockNodes are battery-operated and can therefore be
integrated in the SimonsVoss WaveNet with no wiring whatsoever. This makes the
system ideal for later installation in an existing building.
The wired variant of the LockNode (WN.LN.C) features connections for the RS485
bus and for the external power supply.
(see 7.9).
To simplify installation as far as possible, the housing of the WaveNet LockNode is
designed to be installed in a standard built-in mounting box (60 mm deep,
55 mm in diameter) in accordance with DIN 49073 Part 1 (e.g. for installation in a
light switch panel).
Lock Node
with housing