Unit installation
VdS Shunt lock function 3066
Page 15
Jumper B2 is inserted:
⇒ Maximum transmitting range. For VdS-compliant installation, however, you
must then work with external keys to differentiate between outside and inside.
(Refer to 4.3 VdS-Compliant Installation of the Activation Unit).
⇒ In VdS-compliant installation, the range of the antenna extender is reduced
solely by the correct use of the aluminum sleeve. (Refer to 4.3 VdS-Compliant
Installation of the Activation Unit).
2.4.1 Testing the Slave Activation Unit (SA):
Before final installation, apply voltage to contacts 1 and 2 of the activation unit
(compound battery). Make sure that the polarity is correct. Do not wire the other
contacts for this test.
Transponder
slave activation unit 1 cm to max. 3 cm (.4 to 1.2 inches)
L This corresponds to the strongly reduced range when the screening sleeve is
inserted on the antenna extender (refer to Chap. 4.3).
Make sure that all components are correctly programmed (refer to Chap. 3). Insert
jumper B1 on the right. Then test whether the relay on the activation unit switches
(soldering terminals 5 and 7) by operating the transponder two times in quick
succession (within 0.5 ... 2 sec.).
Then you must convert the acoustic activation acknowledgement to BAC operation
(insert jumper B1on the left) and test it by attempting to activate the system. Once the
slave activation unit successfully passes the test, you can carry out the actual
permanent installation.
2.4.2 Connecting Power Supply, Sabotage Contacts and Local
Activation Suppression:
• Power supply
Connect the positive pole of a direct current source between +8 ... + 16 V
(recommended: +12 V) to soldering terminal 1. Note that the voltage is not permitted
to
exceed a value of +16 V under any circumstances.
Connect soldering terminal 2 to ground.
• External light emitting diode
You can connect an external light emitting diode to soldering terminals 3 and 4 for
visual signaling. When the transponder is operated successfully, the LED blinks.
Maximum length of the line: 10 m (33 feet).