Unit installation

Transponder 3064
Page 6
Explosion Protection Transponder
2.7 General Information
This special product is a transponder that is permitted to be carried into and used in
areas subject to explosion hazards, called Zone 1. An area is denoted as Zone
1 when atmospheres capable of exploding occur occasionally. It is crucial that you
keep in mind the following issues:
You are not permitted to open the housing.
Unlike with the Transponder 3064, only SimonsVoss Technologies AG is
permitted to change the battery.
Normally, you must comply with the general operating instructions of the
BGR132 (German rules for occupational safety and health) when using the
device in Zone 1.
3.2 Standards
The transponder has been tested according to the applicable explosion protection
standards. Refer to:
Directive 94/9/EC
DIN EN 50014 (Electrical apparatus for potentially explosive atmospheres)
DIN EN 50020 (Intrinsic safety "i")
3.3 Grouping
The transponder is grouped in the following way:
Explosion protection: zone 1
Intrinsic safety: ib
Explosion group: IIC
Temperature class: T3
Device group: II2 G
This applies to areas in which a potentially explosive atmosphere can arise due to
gases, vapours or mists. The information quoted relates to an ambient temperature of
from -20°C to +40° C (-4° F to +104° F) in the place of use.