Unit installation
Smart Relay: SREL, SREL.ZK, SREL.ADV
Page 19
+ / ~
- / ~
NC
COM
NO
Brown
White
Green
Grey
Yellow
Batterie SREL.BAT
Netzteil
{
Relais
{
}
Externe Antenne
SREL.AV
1 K 1 K
GND
+ 5..12VDC
Clock
Data
Externes Zutrittskontroll- oder
Zeiterfassungssystem
F2 F1
Pull Up Widerstände
CLS
1 K
Pull-up resistors
External antenna
SREL.AV
Power supply
Battery SREL.BAT
Relay
External access control or time
recording system
8.3 Kaba Benzing, Siemens, Gantner Legic, Primion, Isgus Interface
9.0 Maintenance
9.1 Battery Warning and Battery Replacement if you are using the
SREL.BAT battery
In case the battery capacity is no longer sufficient, a Smart Relay can issue a battery
warning as follows:
SREL, SREL.ZK, SREL.ADV
Internal LED blinks 8 times each time you operate the transponder and before
the relay is switched.
If you are operating with a battery, you should make sure that this LED can be
seen from the outside.
Only SREL.ADV
External LED blinks 8 times or external buzzer beeps 8 times, each time you
operate the transponder.
Approximately 100 operations are possible after the battery warning, so you
should replace the battery as soon as possible.