Unit installation
Manual – Digital Half Cylinder 3061
Page 17
6.1.1 Schema
6.1.2 Procedure for emergency battery - warehouse mode
Please proceed as follows to change the batteries if the half cylinder is in emergency
battery - warehouse mode:
• Replacing batteries (see chapter Battery change).
• Go to the door and take a Notebook or PDA (having exported the locking
plan) and a programming device with you.
• Select the appropriate locking from the locking plan.
• Program over the cylinder once without making any changes. This deacti-
vates the two battery warning checkboxes and the warehouse mode.
• Use the authorised transponder to engage the cylinder.
The half cylinder will emit the level 2 battery warning once more after the batteries
have been changed. The locking cylinder's electronic system will then detect that the
batteries are at full capacity or have been replaced and the cylinder will work as nor-
mal.
This procedure is only
necessary in emergency battery - warehouse mode. This
mode was introduced to prevent the batteries from completely discharging without in-
tervention by the locking system administrator. Nonetheless, batteries in emergency
battery - warehouse mode should be changed as soon as possible.
Normal operation
Opening by system
administrator only
30 seconds of dou-
ble signal beeps
8x double beeps
Up to 15,000 operations or
9 months
ca. 50 operations or 30
days
Programming device
Residual capacity < 25%
Battery warning level 2:
Extremely weak batteries
Emergency battery -
Warehouse mode
Battery warning level 1:
Weak batteries