Unit installation
Manual – Digital Half Cylinder 3061
Page 15
5.5 Installing the multistage half cylinder
1. Remove the metal plates from the inner tube and slide a plastic plate on to
it. (The plastic plates are included in the packaging!)
2. Now slide the metal plates back on to the inner tube so that one plastic
plate and a number of metal plates determined by the half cylinder model
are located on the inner tube.
3. Carefully insert the inner tube into the profile cylinder housing up to the
stop.
4. Use an authorised transponder to engage the half cylinder.
5. With the half cylinder engaged, push the knob lightly against the profile cyl-
inder housing whilst turning it clockwise until the inner tube snaps into the
profile cylinder housing.
& Pull lightly on the knob whilst turning to and from to check whether the
inner tube has snapped properly into place.
& The plastic plates are included in the packaging!
When you assemble the unit, make sure that only one plastic plate and the ex-
act same number of metal plates as during disassembly are located on the in-
ner tube! The plastic plate must be located directly against the knob.
5.5.1 Perform a function test
1. Engage the half cylinder using the transponder; with the door open, turn
the knob in both directions for opening and locking. The knob should turn
freely in both directions.
2. Close the door and repeat the test. If the knob is difficult to turn you will
need to adjust the door or the striking plate.
The same applies in general to installation in a key-operated switch.