Unit installation
Manual – Digital Half Cylinder 3061
Page 9
This function is especially practical for network-based programming or data reading, as
the acoustic signal emitted by the half cylinder is not usually audible due to the dis-
tance.
3.8 Logging unauthorised access attempts
As a rule, the system only logs authorised transponder operations. You will need to se-
lect this option if you wish to log attempts to open the door using an unauthorised
transponder.
Unauthorised access attempts include:
• Access attempts without authorisation
• Access attempts outside of the authorised time zone
• Access attempts under activated alarm system and simultaneous use
of a SimonsVoss shunt lock.
As a general rule the system only logs transponders belonging to the same
locking system, i.e. they must have the same locking system ID (SID).
3.9 Time-switch function
This is only possible with the .ZK version. The time-switch function requires a time
zone plan to be loaded which then activates the half cylinder during the specified times
(in Group 5 - Locking). For instance, a door could be freely accessible during the day
but only accessible via transponder at night.
Caution: The lock is not activated automatically when the knob is disengaged.
The following options are available in the field "Time-controlled activation" when the
time-switch function is selected:
1. Manual disengage
The half cylinder does not
disengage automatically at the appointed time but re-
mains engaged until a subsequent command is received from an authorised
transponder.
2. Automatic disengage (default setting)
The half cylinder disengages automatically at the time appointed in the time zone
plan.
3. Manual engage (default setting)
The half cylinder does not engage automatically at the appointed time but re-
mains disengaged until a subsequent command is received from an authorised
transponder.
4. Automatic engage