Unit installation

Manual – Digital locking cylinder 3061
Page 25
7. Signal tones
Signal type Meaning Required action
2 short tones prior to engaging
and one short tone after
disengaging
Normal operation None
Battery warning level 1:
8 short tones prior to engaging
Batteries will soon be empty Change the cylinder batteries
Battery warning level 2:
8 short tones for 30 seconds
with a one-second break
between each set
Batteries are nearly
completely discharged
Replace the cylinder
batteries immediately!
8 short tones after disengaging Transponder battery empty
Have the transponder battery
changed
1 short signal tone without
engaging the cylinder
Attempt to operate outside
of time zone
Armed alarm system with
simultaneous use of a
SimonsVoss shunt lock
None
8. Battery change
8.1 General notes
Batteries should only be changed by trained personnel. Only use batteries
approved by SimonsVoss.
On anti-panic cylinders these steps should be carried out on the external knob
as the batteries and electronics are located on the external side.
Please see the data sheet for further information.
& Reversing polarity can result in damage to the locking cylinder. The
batteries used in this device can cause fire or burns if handled
incorrectly. Do not charge, open, heat above 100°C, short-circuit or burn
batteries.