Unit installation
Manual – Digital locking cylinder 3061
Page 23
Warning level 2: extremely weak batteries
If the batteries are allowed to discharge even further, subsequent transponder
operation will induce a succession of short signal tones lasting approximately
30 seconds before the cylinder engages. The cylinder will not engage until
after the acoustic signal has ended. The batteries are now virtually completely
discharged. It is imperative they are replaced as soon as possible.
Emergency battery - warehouse mode:
A locking cylinder that has indicated battery warning level 2 will remain active
for approximately another 50 operations, or it will shut down completely after
approximately 30 days if not used. In both cases the locking cylinder will revert
back to the so-called emergency battery - warehouse mode. The locking
cylinder can now only engage with the help of a programming device (see
chapter 6.1.3).
6.1.1 Schema
Normal operation
Opening by system
administrator only
30 secs. of double
signal beeps
8x double beeps
Up to 15,000 operations or
9 months
ca. 50 operations or 30
days
Programming device
Residual capacity < 25%
Battery warning level 2:
Extr. weak batteries
Emergency
battery
-
warehouse
mode:
Battery warning level 1:
weak batteries