Service manual

TP0332/2 2.7
AUDIBLE ALERTS
Various tones are available to alert the user to the radio’s call and error states.
Table 2.3 Alert Tones
CUSTOMIZATION DATA
The SRP8000 Series functionality depends on the customization data which has been loaded. An
SRP8000 series radio may be supplied with a ‘Factory Default’, or customer specific customization data.
An SRP8000 Series Programmer may be used to customize a radio.
Details are given in the SRP8000 Series Data Programmer User Guide (TP1858).
Alert Tone/Tones
Valid Key Press ‘Key Click’ (if enabled) 1800Hz for 0,05s.
Invalid Key Press (if enabled) 400Hz for 0,15s.
Battery Low (if enabled) 400Hz, 0,2s on, 0,1s off, 0,2s on - repeated five times every
minute until battery on charge, or replaced.
Transmit Time-out Warning 1800Hz, 0,1s on, 0,9s off, repeated until Transmit Time-out.
Call Alert type 1 771Hz, 0,15s on, 0,3s off, repeated for up to four seconds or
until a key is pressed.
Call Alert Type 2 771Hz for 0,5s.
UK Ringing Tone 771Hz, 0,4s on, 0,2s off, 0,4s on, 0,2s off, repeated every 3
seconds until a key is pressed.
European Ringing Tone 771Hz, 0,4s on, 0,2s off, repeated until a key is pressed.
Group Call 1200Hz, 0,2s on, 0,1s off, 0,2s on.
Urgent Call 1200Hz, 0,2s on, 0,1s off, 0,2s on, 0,1s off, 0,2s on, 0,5s off
repeated five times or until a key is pressed.
Transmit Inhibit 1800Hz, 0,375s on, 0375s off, repeated once.
Remote Reset 1200Hz for 0,05s.
Error Lock (Synthesizer cannot lock) 400Hz, 150ms on, 150ms off, repeated five times.