To comply with Industry Canada RF radiation exposure limits for general population, the
antenna(s) used for this transmitter must be installed on outdoor permanent structures and detailed
RF exposure condition(s) are to be evaluated at the time of licensing. In addition, the antennas of
this transmitter must not be collocated with other antennas or transmitters.
HUMAN EXPOSURE TO RADIO FREQUENCY RADIATION (FCC)
WARNING
TO COMPLY WITH THE MAXIMUM PERMISSIBLE EXPOSURE (MPE)
LIMITS REFERENCED IN 47 CFR 1.1310 TABLE 1, THE FOLLOWING
MINIMUM SAFE OPERATING DISTANCES MUST BE OBSERVED FOR
THE GENERAL PUBLIC:
When using a 0dBd (2.14 dBi Dipole antenna)
150 to 174 MHz: 0.4 m
406.1 to 480 MHz: 0.35 m
480 to 512 MHz: 0.32 m
If a directional antenna is used then the additional antenna gain must be taken
into consideration.
When using a 6dBd (8.14 dBi Dipole antenna)
150 to 174 MHz: 0.8 m
406.1 to 480 MHz: 0.7 m
480 to 512 MHz: 0.64 m
HUMAN EXPOSURE TO RADIO FREQUENCY RADIATION (INDUSTRY CANADA)
WARNING
TO COMPLY WITH THE MAXIMUM PERMISSIBLE EXPOSURE (MPE)
LIMITS REFERENCED IN RSS-102 Issue 5, THE FOLLOWING MINIMUM
SAFE OPERATING DISTANCES MUST BE OBSERVED FOR THE
GENERAL PUBLIC:
When using a 0dBd (2.14 dBi Dipole antenna)
138 to 174 MHz: 0.50 m
406.1 to 470 MHz: 0.45 m
If a directional antenna is used then the additional antenna gain must be taken
into consideration.
When using a 6dBd (8.14 dBi Dipole antenna)
138 to 174 MHz: 1.00 m
406.1 to 470 MHz: 0.90 m