A minimum of 85 dB transmit-receive isolation should be provided by the antenna system and associated
filters.
It is recommended that a good quality flexible co-axial cable is used, e.g. with double-screening braid and
multi-strand copper inner.
CAUTION
The Antenna System should be protected against lightning by means of an earthing
system and surge protection device.
Do not connect Antenna Lightning conductors to the base station or Mains Earth.
Power Connection
The DC power input is via a 2-pin IP67 DC plug connector. The two pins are wired to suit the voltage range
shown in Table 2 below.
Table 2. DC Power Connector Pin-outs.
Pin Description
1 +14.0 V
2 Ground
Figure 2. 2-pin IP67 DC Power Connector.
The equipment must be installed so that the power socket is readily accessible.
Earth Point
The earth stud on the rear panel is provided for protective earthing of the equipment. This should be
connected using heavy duty earthing wire with as few bends as possible, typically 6 mm Green/Yellow with
5 mm eyelet tag.
P3 USB A Dual
The USB Type A connector is used as the host connection. The connector pin-outs are detailed below in
Table 3.
Table 3. USB Type A Connector Pin-outs.
Pin Function
1 Vcc (+5 V)
2 Data -
3 Data +
4 Ground