Manual
Installation 8
Process C. 2. Install a deep well pump
(3205C, 3207C, 3210C)
Deep We[[ Pump Installation
(4" or Larger Diameter Cased Well)
For wells over 25, but not exceeding 70 feet in depth, the
1 HP Convertible Deep Well Pump is recommended. However,
the 1/2 HP or 3/4 HP Deep Well Pump may also be used for
depths not exceeding 70 feet.
Genera[ materials needed for the convertible pumps:
* One can PVC cement (read instructions careful[y)
e One can thread compound (read instructions carefully)
e Two 1" female PVC adapters
, Enough rigid 1-1/4" and 1" PVC pipe and couplings to
reach from bottom of well to pump (delivery pipe)
e One 1-1/4" PVC elbow
e One 1-1/4" male PVC adapter
e One pressure regulator Kit (includes fittings, tubing, and
1/4" plug)
e One pressure gauge
• Two male 3/4" PVC adapters
• Enough rigid 3/4" PVC pipe to reach from pump to pressure
tank to service line
• Tank tee (for diaphragm pressure tanks)
• Two 1/4" plugs
• One 1/2" drain cock
In addition to Genera[ Materia[s fur Deep We[[ Pumps
• One 1-1/4" foot valve
• One 1-1/4" close nipple
• One ejector
• One 1" x 5" nipple
• One 1-1/4" female adapter
• One we[[ sea[
• Enough rigid 1" PVC pipe and couplings to reach from
bottom of we[[ to pump (pressure pipe)
• One 1" PVC elbow
• Two 1-1/4" male PVC adapters
• One 1" x 4" nipple
Reminder: All joints and connections must be airtight. A single pinhole leak will prevent the
proper operation of the pump. Use thread compound on all threaded connections unless
specified otherwise.
To Install A Convertible Jet Pump:
1.
Thread 1-1/4" close nipple into foot
valve. Thread the other end of 1-1/4"
close nipple into bottom of deep we[[
ejector. Hand tighten, then tighten
1/4 turn with pipe wrench.
_ EJECTOR
1-1/4"
_ CLOSE
NIPPLE
._ FOOT
VALVE
2.
The ejector has two holes in the top
of it. Confirm nozzle is installed.
Thread deep well venturi tube (longer
tube) into larger hole until snug.
Thread 1" x 5" nipple into smatter
hole. Only hand tighten venturi tube.
Hand tighten nipple 1/4 turn with
pipe/crescent wrench.
=-_ 1"x5"
i ///Nipple
_ _ ]j Venturi
Ejector
3.
Thread a 1-1/4" mate PVC adapter
over the venturi tube and into
ejector. Thread a 1" female PVC
adapter onto the 1" x 5" nipple.
Hand tighten adapters 1/4 turn with
pipe/crescent wrench.
4.
Subtract five feet from the depth of
your we[[. This is the total length
of PVC pipe and couplings to
cement onto both 1-1/4" male and
1" female PVC adapters. Cement
a section of PVC pipe to each
adapter, then lower the whole
assembly into the well, foot valve
first. Firmly clamp the end of the
PVC pipes with a pipe clamp to prevent the assembly from
sliding down into well.