hardware design v1.00

Table Of Contents
Smart Machine Smart Decision
1200, 2400, 4800, 9600, 19200, 38400 and 57600bps
z The default setting is autobauding.
Autobauding allows SIM968 to automatically detect the baud rate of the host device. Pay more attention to the
following requirements:
z Synchronization between DTE and DCE:
When DCE powers on with autobauding enabled, user must firstly send character “A” to synchronize the
baud rate. It is recommended to send “AT” until DTE receives the “OK” response, which means DTE and
DCE are correctly synchronized. For more information please refer to the AT command “AT+IPR”.
z Restrictions of autobauding operation:
The DTE serial port must be set at 8 data bits, no parity and 1 stop bit.
The URC such as "RDY", "+CFUN: 1" and "+CPIN: READY” will not be reported.
Note: User can use AT command “AT+IPR=x” to set a fixed baud rate and the setting will be saved to non-volatile flash
memory automatically. After the configuration is set as fixed baud rate, the URC such as "RDY", "+CFUN: 1" and "+CPIN:
READY” will be reported when SIM968 is powered on.
Debug port:
z Used for debugging and upgrading firmware.
z Debug port supports the baud rate of 115200bps for debugging and 460800bps for upgrading firmware.
4.6.2 Software Upgrade and Debug
Refer to the following figure for debugging and upgrading software.
Figure 21: Connection for software upgrading and debugging
The serial port and the debug port support the CMOS level. If user connects the module to the computer, the
level shifter should be added between the DCE and DTE.
For details about software upgrading, please refer to document [4].
SIM968_Hardware Design_V1.00 2013.02.25
30