4.2.2.3 Over-voltage or Under-voltage Power down
The module software monitors the VBAT voltage constantly.
If the voltage 3.3V, the following URC will be reported:
UNDER-VOLTAGE WARNNING
If the voltage 4.7V, the following URC will be reported:
OVER-VOLTAGE WARNNING
If the voltage < 3.2V, the following URC will be reported, and the module will be automatically powered down.
UNDER-VOLTAGE POWER DOWN
If the voltage > 4.8V, the following URC will be reported, and the module will be automatically powered down.
OVER-VOLTAGE POWER DOWN
At this moment, AT commands can not be executed any more, and only the RTC is still active. Power down mode
can also be indicated by STATUS pin, which is at low level at this time.
4.2.2.4 Over-temperature or Under-temperature Power down
The module will constantly monitor the temperature of the module,
If the temperature > +80, the following URC will be reported:
+CMTE: 1
If the temperature < -30, the following URC will be reported:
+CMTE:-1
If the temperature > +85, the following URC will be reported, and the module will be automatically powered
down.
+CMTE: 2
If the temperature < -40, the following URC will be reported, and the module will be automatically powered
down.
+CMTE:-2
At this moment, AT commands can not be executed any more, and only the RTC is still active. Power down mode
can also be indicated by STATUS pin, which is at low level at this time.
The AT command “AT+CMTE” could be used to read the temperature when the module is running.
For details please refer to document [1].
4.2.3 Restart SIM908 by PWRKEY Pin
When the module works normally, if the user wants to restart the module, follow the procedure below:
1) Power down the module.
2) Wait for at least 800mS after STATUS pin changed to low level.
3) Power on the module.
Figure 15: Timing of restart SIM908