Specifications
Table Of Contents
- 1 Introduction
- 2 Package Information
- 3 Interface Application
- 4 Antenna Interfaces
- 5 Electrical Specifications
- 6 Appearance
- 7 Packaging
- 8 Appendix
SIM6600-M2 Hardware Design V1.00
www.simcom.com
38
/
54
I
IL
Input low leakage current(no pull
up resistor)
TBD - - uA
These parameters are for digital interface pins, such as UART, I2C, I2S, RESET#, ANTCTL and GPIOs
(DPR, SIM DETECT).
The operating temperature of Module is listed in the following table.
Table 30:Operating temperature
Parameter Min. Typ. Max. Unit
Normal operation temperature(3GPP
compliant)
-25 25 75
℃
Extended operation temperature* TBD TBD TBD
℃
Storage temperature -40 25 80 ℃
Module is able to make and receive voice calls, data calls, SMS and make UMTX/LTE traffic in
extended operation temperature. The performance will be reduced slightly from the 3GPP
specifications if the temperature is outside the normal operating temperature range and still within the
extreme operating temperature range.
5.3 Operating Mode
5.3.1 Operating Mode Definition
The table below summarizes the various operating modes of Module product.
Table 31: Operating mode Definition*
Mode Function
Normal
operation
UMTS/LTE
Sleep
AT command “AT+CSCLK=1” can be used to set the module to a sleep
mode. In this case, the current consumption of module will be reduced to
a very low level and the module can still receive paging message and
SMS.
NOTE
NOTE