User's Manual

Smart Machine Smart Decision
SIM7600E-H_User Manual_V1.00 2017-10-11
6.3 Typical SMT Reflow Profile
SIMCom provides a typical soldering profile. Therefore the soldering profile shown below is only
a generic recommendation and should be adjusted to the specific application and manufacturing
constraints.
Figure 36: The ramp-soa
k-spike reflow profile of SIM7600E-H
Note: For more details about secondary SMT, please refer to the document [21].
6.4 Moisture Sensitivity Level (MSL)
SIM7600E-H is qualified to Moisture Sensitivity Level (MSL) 3 in accordance with JEDEC
J-STD-033. If the prescribed time limit is exceeded, users should bake modules for 192 hours in
drying equipment (<5% RH) at 40+5/-0°C, or 72 hours at 85+5/-5°C. Note that plastic tray is not
heat-resistant, and only can be baked at 45° C.
Table 36: Moisture Sensitivity Level and Floor Life
Moisture Sensitivity Level
(MSL)
Floor Life (out of bag) at factory ambient≤30°C/60% RH or as
stated
1 Unlimited at 30/85% RH
2
1 year
2a 4 weeks
3 168 hours
4 72 hours
5 48 hours
5a 24 hours
6
Mandatory bake before use. After bake, it must be reflowed within the