User's Manual

Smart Machine Smart Decision
SIM7600SA_User Manual_V1.00 2017-10-11
TXB0108RGYR provided by Texas Instruments is recommended. The following figure shows the
voltage matching reference design.
Figure 15: Reference circuit of level shift
To comply with RS-232-C protocol, the RS-232-C level shifter chip should be used to connect
SIM7600SA to the RS-232-C interface, for example SP3238ECA, etc.
Note: SIM7600SA supports the following baud rates: 300, 600, 1200, 2400, 4800, 9600, 19200,
38400, 57600, 115200, 230400, 460800, 921600, 3200000, 3686400, 4000000bps. The default
band rate is 115200bps.
3.3.2 RI and DTR Behavior
The RI pin can be used to interrupt output signal to inform the host controller such as application
CPU.
Normally RI will keep high level until certain conditions such as receiving SMS, or a URC report
coming, and then it will change to low level. It will stay low until the host controller clears the
interrupted event with “AT+CRIRS AT command.
Figure 16: RI behaviourSMS and URC report
Normally RI will be kept at a high level until a voice call, then it will output periodic rectangular
wave with 5900ms low level and 100ms high level. It will output this kind of periodic rectangular
wave until the call is answered or hung up.