User manual
RS232 Status Response
The returned data format (in response to a status request) takes the following format:
Message header = $02 as per Figure 7 above (0 = RS232 address).
Message data:
$02VEXCSXSDXSSXSAXAV=XX SVXCVX No=XX Nv=XX Pt=XX Nt=XX Sv=XX E2X SWX TVX H,G=XX,X XX,X XX,X XX,X XX,X
Note that the mnemonics are the same as for the received RS232 commands. Message contents are
defined in the following table:
Mnemonic Meaning Data
VE Currently Selected Channel (all MUXes) 1 - 5 = Channel Number
CS Compander Status 0 = Off
1 = On
SS Standby Mode 0 = Off
1 = On
SD Dimmer Status 1 - 4 (1 = Min Level)
SA Auto Input Mode Status 0 = Off
1 = On
AV,SV,CV,No,Nv,Pt,Nt,Sv,E2,SW,TV Internal Sima Repair Diagnostics
H,G Hue and Gain Setting for Each Channel Factory default:
20,1 20,1 20,1 20,1 20,1
IR commands take precedence over front panel key presses. Thus, if an IR command is received at the
same time as one of the front panel buttons is pressed, the IR command will be executed and the button
press ignored. However, RS232 commands take precedence over both IR and front panel commands, so if
an RS232 command is received at the same time as an IR command, the IR command will be ignored.
Example:
Unit channel: 0
To turn standby mode off: @0SS0
To turn dimmer status down 1 level: @0SD?
To lock-out front panel: @0SP1
To set auto input mode on: @0SA1
Page 18