Installation manual

C3X LINK
30
31
11 TROUBLESHOOTING GUIDE
No power (LEDs always OFF)
Check that the units’ power switches are set to I.
Check that the power cables are correctly connected to
the units’ power sockets.
Check the condition of the fuse located on the power
socket on the rear of the Projector.
Replace the fuse located on the Projector power socket with an
identical type (T 5A H).
If the fuse blows repeatedly, seek technical assistance from
your nearest Dealer.
Lamp fails to switch on
Allow a few minutes between switching off and switching on
again. This will allow the lamp to cool down sufficiently.
If the lamp fails to illuminate - even though the unit has
had time to cool down - seek technical assistance from
your nearest Dealer.
Check the state of the connection by interpreting the code
displayed by the system LEDs in accordance with Table 3.
No image
Make sure the selected input is connected to a video or
graphic signal and that the relevant source is functioning
correctly.
Make sure the video or graphic signals supplied by the
source are compatible with the C3X-LINK system’s technical
specifications and, in particular, with those of the selected
input.
Check the condition of the cables used to connect the
DigiOptical™ Image Processor to the various sources.
Check the state of the connection between the DigiOpti-
cal™ Image Processor and the Projector.
Check the state of the connection by interpreting the code
displayed by the system LEDs in accordance with Table
3.
Make sure the cooling air vents on the units are not blocked
and that the ambient temperature is below 35°C.
Make sure you have followed the power-up procedure
properly.
Image is disturbed, unstable or noisy
Check compatibility of the video or graphic signals with
the technical specifications of the system, and specifically,
with the specifications of the selected input.
Check the condition of the cables used to connect the
DigiOptical™ Image Processor to the various sources.
If the problem occurs on a terrestrial broadcast source
signal, check that the receiver has been correctly tuned
in and that the aerial system is in good working order.
If the problem occurs in a video signal from a videorecor-
der, ensure that the videotape is an original first gene-
ration” copy and that VCR mode is active in the PICTURE
menu.
Adjust the Sharpness parameter in the PICTURE menu to
optimise the projected image.
10 CLEANING AND MAINTENANCE
The DigiOptic™ Image Processor do not require internal adjust-
ments and do not contain any user-serviceable parts.
To change the lamp, or for any repairs, always contact your
nearest technical service centre that will resolve all your pro-
blems in a courteous and efficient manner.
To clean the outer cover of the projector use a soft cloth and
moisten slightly if necessary with water and a small amount of
neutral soap. Do not rub hard on the printed captions on the
rear panel.
The lens may be cleaned with a very soft, non-abrasive small
brush, in order to remove dust particles. Alternatively, use a soft
dry cleaning cloth (of the type used for camera lens cleaning)
to remove fingerprints and grease marks.
CLEANING AND MAINTENANCE - TROUBLESHOOTING GUIDE