Installation manual

16
C3X LINK
17
The C3X-LINK system consists of two units (DigiOptic™ Image
Processor and Projector) of which the former is also the system
control centre.
The system can be controlled from either the remote control
(via the infrared sensors on the DigiOptic™ Image Processor
and on the Projector) or the keypad located on the back of
the Projector.
However, the power supply to the two units is separate.
After interconnecting the units via the fibre optic cable, connect
them to the electrical mains supply:
1) Set the Projector power switch on the rear panel onto “I” (ON)
(Fig.13 phase A).
2) Set the DigiOpticTM Image Processor switch on the external
power supply unit to “I” (ON) (Fig. 13 phase B). In this phase
make sure the DigiOptic Image Processor (Fig. 13 phase
C) is in the OFF position: in this condition the indicator LEDs
on the front panel of the DigiOptic Image Processor should
not be lit.
The power-up sequence described at points 1 and 2 must
be observed in full; otherwise the system will not initialise
properly and the power-up sequence must be repeated in
accordance with the proper procedure.
3) Press the central button on the front of the DigiOptic™ Image
Processor onto ON (Fig.13 phase C).
After a few seconds (system initialisation interval), the DigiOp-
tic™ Image Processor and the Projector assume stand-by
mode.
System status information is provided by two LEDs (green and
blue) on the front panel of the DigiOptic™ Image Processor
and on the rear of the Projector.
Significant status signals are given in Table 3.
If the “No optical linkor “Errorsignals are active the system
cannot be operated; if the Warning” signal is active the
system will operate but it may be unable to read certain
input signals correctly.
4) Switching on the system (Fig.14):
• with the remote control ( keys)
• with the Projector keypad ( key)
Off
Initialisation
Status
DigiOptic™ Image
Processor
Projector
Led green Led blue Led blue Led red SIM2
RED
BLUE
RED
BLUE-OFF
BLUE
RED-BLINK
RED
RED
BLU
Standby
On
Cooling
Link error
Controller error
Fan failure
Overtemperature
Init error (Warning)
: Off
: On
: Blinking
---
8 SWITCHING ON AND OFF
O
I
O
I
IMAG
E
P
R
O
C
E
SSO
R
O
FF
ON
D
IG
I
O
P
T
I
C
IMA
G
E
P
R
O
C
E
S
S
O
R
O
F
F
ON
A
B
C
~ AC IN
FUSE
T
5A H 250V~
CLASS
1 LASER
PRODUC
T
ESC
MENU
SOUR
CE
CAUTION:
for continued
protection against risk of
fire, replace
only with same type and rating fuse.
ATTENTION: pour ne pas compromettre la protection con
tre les resques
d’incndie remplacer par un fusible de meme type et de
mems caracteristique.
A TEXAS INSTR
UMENTS TECHNO
LOGY
1
2
3
-
0
I
~ AC IN
FUSE
T
5A H 250V~
ESC
SOURCE
rotection contre les resq
ues
type et de mems carac
teristique.
0
I
FUSE
T
5A H 250V~
CLASS 1 LASER PRODUCT
ESC
MENU
SOURCE
CAUTION:
for continued
protection against risk of
fire, replace
only with same type and rating fuse.
ATTENTION: pour ne pas compromettre la protect
ion contre les resques
d’incndie remplacer par un fusible de meme
type et de mems caracteristique.
A TEXAS INSTRUM ENTS TEC HNOLOGY
1
2
3
-
0
I
RC
I 2005
LI
G
H
T
?
?
D
Fig.14
Fig.13
Table 3
SWITCHING ON AND OFF