DLP Video Projector Specification Sheet
SIM2 C3X LINK
RS-232C CONTROL SPECIFICATIONS
12
21 22 23 24 25 26 27 28 29 30 31 32
00 00 00 00 00 00 00 00 00 00 00 00
Get Codes
Get Commands may be used to get the current value of projector parameters.
The response to a correct Get Command consists of 33 byte packet, where Byte Number 11 contains the
Validation Code (01) and bytes Number 17 and Number 18 the requested value (the least-significant byte of
the value being sent first). Of course CRC (bytes number 6 and 7) has been altered accordingly.
0 1 2 3 4 5 6 7
1E BE EF
Packet Type Packet Payload Size Packet Checksum (CRC)
8 9 10 11 12 13 14 15 16 17 18 19 20
Op Type
Op ID
01 00
Op Target
00 00
Req Value
00 00
21 22 23 24 25 26 27 28 29 30 31 32
00 00 00 00 00 00 00 00 00 00 00 00
Get Codes:
BRIGHTNESS
BE EF 03 19 00 52 2A 02 00 08 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
(1)
CONTRAST
BE EF 03 19 00 C7 77 02 01 08 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
(1)
COLOR
BE EF 03 19 00 38 93 02 02 08 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
(2)
TINT
BE EF 03 19 00 AD CE 02 03 08 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
(3)
COLOR TEMPERATURE
BE EF 03 19 00 9D 0B 02 C2 09 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
(4)
GAMMA
BE EF 03 19 00 13 25 02 27 08 00 00 00 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
(5)
MEMORY
BE EF 03 19 00 5E D5 02 27 09 00 00 01 00 00 00
00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
(6)