Manual
2.2. SAFETY
CB: IEC 60950~1:2005(2nd Edition) and/or EN 60950~1:2006 +A11:2009
UL: UL 60951-1 , 2nd Edition, 2007-03-27
TUV: EN 60950-1:2006+All
3.2. INRUSH CURRENT
Maximum inrush current from power-on (with power on at any point on the AC sine)
and including, but not limited to, three line cycles, shall be limited to a level below
the surge rating of the input line cord, AC switch if present, bridge rectifier, fuse, and
EMI filter components. Repetitive ON/OFF cycling of the AC input voltage should not
damage the power supply or cause the input fuse to blow.
3. INPUT ELECTRICAL SPECIFICATIONS
3.1. AC INPUT
◆ Nominal voltages for test purposes are considered to be within ±1.0V of nominal.
Parameter Mi n. Nom. Max. Unit
Vin (115VAC) 90 115 132 VAC rms
Vin (230VAC) 180 230 264 VAC rms
Vin Frequency 47 -- 63 HZ
(1)
3.3. INPUT LINE CURRENT & POWER FACTOR (P.F.)
(At Full load)
AC input Input line current P.F.@ Full Load P.F.@ Pin=75W
115V < 3.5 Amps – rms > 0.95 > 0.8
230V < 2.0 Amps – rms > 0.9 > 0.65