Manual

2.2. SAFETY
CB: IEC 60950~1:2005(2nd Edition) and/or EN 60950~1:2006 +A11:2009
UL: UL 60951-1 , 2nd Edition, 2007-03-27
TUV: EN 60950-1:2006+All
3.2. INRUSH CURRENT
Maximum inrush current from power-on (with power on at any point on the AC sine)
and including, but not limited to, three line cycles, shall be limited to a level below
the surge rating of the input line cord, AC switch if present, bridge rectifier, fuse, and
EMI filter components. Repetitive ON/OFF cycling of the AC input voltage should not
damage the power supply or cause the input fuse to blow.
3. INPUT ELECTRICAL SPECIFICATIONS
3.1. AC INPUT
Nominal voltages for test purposes are considered to be within ±1.0V of nominal.
Parameter Mi n. Nom. Max. Unit
Vin (115VAC) 90 115 132 VAC rms
Vin (230VAC) 180 230 264 VAC rms
Vin Frequency 47 -- 63 HZ
(1)
3.3. INPUT LINE CURRENT & POWER FACTOR (P.F.)
(At Full load)
AC input Input line current P.F.@ Full Load P.F.@ Pin=75W
115V < 3.5 Amps – rms > 0.95 > 0.8
230V < 2.0 Amps – rms > 0.9 > 0.65