manual

03
2.2 DC Load Requirements
Notes:
(1) The maximum continuous total DC output power shall not exceed 750 Watts.
(2) The maximum continuous combined load on +5V and +3.3V outputs shall not exceed 180
(3) The maximum continuous combined load on +12V1& +12V2 outputs shall not
exceed 720
2.3 Cross Regulation
The DC loads shall remain within the ranges specified in 2-2 DC Load Requirements and
the DC output voltages also shall remain within the regulation ranges specified in 2-1
Output Regulation when measured at the load end of the output connectors.
2.4 +5V standby voltage
The +5Vsb is on whenever the AC power is present.
1.0
1.0
1.0
0.0
1.0
0.1
Min
30
25
35
0.8
25
3
MaxOutput Voltage
+5V
+12V1
+12V2
-12V
+3.3V
+5Vsb
Units
Amps
Amps
Amps
Amps
Amps
Amps
Nom
15
12.5
17.5
0.4
12.5
1.5
200
150
100
50
0
50 150 200 300 400 500 600
750W Cross Regulation
(+5V rail +3.3V vs. 12V)
12V power (watts)
5V +3.3V power (watts)
Combined Power
atts (60A).W
atts.W
(4) The maximum continuous combined load on +5V, +3.3V and +12V1~2 outputs shall not
exceed 726 atts.W
720
(5V rail + 3.3V rail)