manual
02
1.3.1 Cold Start
1.3.2 Warm Start
1.4 AC Input Current
1.5 Efficiency
Power supply efficiency >80% at normal AC main voltage input.
2. Output Requirements
2.1 Output Regulations
Note:
(1) The above voltage range should also include ripple and noise.
(2) The output voltage should be measured at the terminals of output connector
.
LimitsConditions
No component over stress or damage should
occur to the power supply.
Input fuse shall not blow.
115/230VAC, full load.
25 C ambient.
UnitsMAXAC Input
12~6115~240V
AMPS
MIN
+5.00
+12.00
+12.00
-12.00
+4.75
+11.40
+11.40
-10.80
Range Normal MAX Units
Volts
Volts
Volts
Volts
Output Voltage
5%
+12.60
+5.25
+12.60
-13.20
+5V
+12V1
+12V2
-12V
LimitsConditions
No component over stress or damage should
occur to the power supply.
Input fuse shall not blow.
Turn off at 132/264V AC full load for 1 sec
then turn on at the peak of the input voltage
cycle at 25 C ambient.
5%
5%
10%
5%
5%
Volts
Volts+3.30
+5.00
+3.14
+4.85
+3.46
+5.25
+3.3V
+5Vsb
ᑻ
ᑻ
±
±
±
±
±
±
ELEMENT ST75EF