After arriving at the customer site, activate and test the Field Service Unit as follows:
CAUTION
DO NOT turn the Field Service Unit ON if
the antenna is not installed. Damage to
the Field Service Unit will result.
1. Plug the Field Service Unit connection cord into the serial port of the laptop computer.
2. Plug a 9 VDC / 500 mA power supply into the Field Service Unit power socket.
CAUTION
Using anything other than a 9 VDC /
500 mA power source may damage the
Field Service Unit.
3. Turn on the Field Service Unit. An indicator light will shine if the
Field Service Unit power supply is functioning correctly.
Installation Procedure
1. Remove index register from C&I gas meter. For American, Rockwell and Sprague meters, remove the index
register and replace with the Pulsimatic pulse output register or the RioTronics index register with pulse output.
For a Roots meter interface, attach the appropriately modified register head with pulse output to the meter before
installing the pulse output pickup device.
2. Attach the Silver Spring Networks C&I Gas Meter Interface (p/n 1620-05001) to a surrounding fixture to the gas
meter. Fixturing locations can include the meter piping, meter fixturing brackets or surrounding structures.
3. Attach the cable assembly from the Pulsimatic or RioTronics pulse output generator to the Silver Spring Networks
C&I Gas Meter Interface (p/n 1620-05001). The cable assembly attaches with a ‘push and twist’ lock for the
weather-resistant seal.
Start the Field Service Application
Note
See Silver Spring Networks publication 98-00001 (Field Service Application User’s Guide) for a more detailed
explanation of FSA operation.
1. Turn on the laptop computer.
2. Launch the FSA software. No error messages will display if the connection between the computer and the Field
Service Unit is working.
3. Log in to the Field Service Application.
Install the Pulse Output Interface Device
For American/Sprague and Rockwell meters, interface with either the Pulsimatic pulse output adapter or the
RioTronics adapter.
Install the Pulsimatic unit in line with the index register and upon installation of the unit, replace the index register
on top of the Pulsimatic.
Install the RioTronics-enabled index register in place of the existing index register.
For Dresser Industries’ Roots meters, please follow the instructions for installation of the RioTronics Interface module.
Install the Silver Spring Networks C&I Gas Meter Interface radio device to the surrounding structure which can
include the meter piping, meter fixtures/supports or some adjacent structure to the meter.