User's Manual
Table Of Contents
- FCC WARNING STATEMENT
- Note
- Preface……………………………………………………………………………………………………. iv
- Chapter 1 Theory of Operation…………………………………………………………………… 1-1
- Start the Field Service Application
- Install the Pulse Output Interface Device
- Setup the Radio for Communication through the Gateway
- Table 3-1 Troubleshooting the C&I Gas Meter Interface
- Table 3-2 Troubleshooting the Laptop Computer/Field Service Unit
Applicant: Silver Spring Networks, Inc. Gas Pulse Interface FCC ID:OWS-963
Install the Pulse Output Interface Device
For American/Sprague and Rockwell meters, interface with either the Pulsimatic pulse output adapter or the
RioTronics adapter.
• Install the Pulsimatic unit in line with the index register and upon installation of the unit, replace the index
register on top of the Pulsimatic.
• Install the RioTronics-enabled index register in place of the existing index register.
For Dresser Industries’ Roots meters, please follow the instructions for installation of the RioTronics Interface
module.
Install the Silver Spring Networks C&I Gas Meter Interface radio device to the surrounding structure which can
include the meter piping, meter fixtures/supports or some adjacent structure to the meter.
Connect the meter pulse output device to the C&I Gas Meter Interface by using the weather-resistant cable assembly
from the pulse output device.
Setup the Radio for Communication through the Gateway