User Instructions

Document Type: Test Procedure
Equipment Name: Innovatec C and I Electric
Author: Dithien V. Ho, RF Design Engineer.
Page 9 of 24
3.3. C&I Electric Communications and Functional Test
3.3.1. General device setup in NCTT:
For “DEVICE”, select “Electric IMU” and “Device ID” select “7”
For “TRANSMIT”, selectCHANNEL= 0 (Default for untested Relay PCA)
The following Transmit options areunchecked”:
“Auto Repeat
“Scan”
“Wakeup/IMU”
(The untested Relay UUT Communication Channel defaults initially to Channel 0; if unable to establish a
communications link between the FSU and the Relay UUT, try to scan all channels for the UUT. Select
Query Serial Numbers” message type, “Select Scan”, and press “Transmit”, then observe the reply
message to identify the Relay communications channel setting.)
FIGURE 2