User Instructions
Document Type: Test Procedure
Equipment Name: Innovatec C and I Electric
Author: Dithien V. Ho, RF Design Engineer.
Page 3 of 24
1. Equipment Requirements
DVM (Digital voltmeter) with ohm and amp functions.
(Bel MERIT, DX451)
Dual Channel Oscilloscope, 100 MHz, 1GBs
(Tektronix, TDS 220)
Variable/Isolation AC Transformer (VIT), 0-150 Vac, 4 Amp
(Global Specialties, 1504)
PC with Windows 95 Operating System
NCTT, Test software, Version 2.2.0 or later
Field Service Unit with Version 2 Communications Chip (Siliconians) NCI installed
Unit Under Test (UUT), in this case the C&I Electric Unit, Fab. Rev. 5.3 or higher, Firmware Ver. 23 or
higher (CnI_V23.HEX, CS = 1c59)
(Innovatec, Relay, Rev. 5.3 or later)
Note: The information in parentheses is a suggested test equipment Manufacturer and Model.
Equivalents may be substituted.