Reference Manual

Table Of Contents
RS9116 n-Link Linux and Android Technical Reference Manual
Version 2.0
August 2019
48
Input Parameters Base Interface (string like rpine0)
The integer value mapping has been shown below:
2 – Select RF_OUT_2/Integrated Antenna
3 – Select RF_OUT_1/U.FL Connector
Output Parameter None
Reset Required No
Usage # ./onebox_util <base_interface> ant_sel <value>
Example The command given below selects the U.FL connector in case of
modules with integrated antenna and will select RF_OUT_1 pin
in the case of the module without an integrated antenna.
# ./onebox_util rpine0 ant_sel 3
Enable Background Scan
and Set Parameters (only
in Client mode)
Description This command is used to enable background scan and set the
relevant parameters. Refer to the section on
Background Scan
Parameters for more details on each parameter.
Default Value 2
Input Parameters Base Interface (string like rpine0)
Background Scan Threshold
RSSI Tolerance Threshold
Periodicity
Active Scan Duration
Passive Scan Duration
Two Probe Enable
Number of Background Scan Channels
Channels to Scan
Note: The OneBox-Mobile software supports DFS slave mode.
However, DFS Channels need to be avoided till the module is
certified for DFS.
Output Parameter None
Reset Required No.