5
32A 40A 48A 80A
CIRCUIT 
REQUIREMENTS
40 Amp
2 pole breaker
50 Amp
2 pole breaker
60 Amp
2 pole breaker
100 Amp
2 pole breaker
RECOMMEND 
WIRING
#8AWG or 
larger gauge 
copper 
wires for the 
conductors 
(NEC 625.17(A)
(2)
#6AWG or 
larger gauge 
copper 
wires for the 
conductors 
(NEC 625.17(A)
(2)
#4AWG or 
larger gauge 
copper 
wires for the 
conductors 
(NEC 625.17(A)
(2)
#2 or 3AWG 
or larger 
gauge copper 
wires for the 
conductors 
(NEC 625.17(A)
(2)
#10AWG 
Green or bare 
copper for 
the ground 
conductor (no 
NEU)
#10AWG 
Green or bare 
copper for 
the ground 
conductor (no 
NEUTRAL is 
used)
#8AWG Green 
or bare copper 
for the ground 
conductor (no 
NEU)
#6AWG Green 
or bare copper 
for the ground 
conductor (no 
NEU)
WARNING
Do not continue this installation until the circuit breaker is turned o.
WIRING AND CIRCUIT REQUIREMENTS
For additional specications, refer to the Specications section.
Installation
Fully  read  and  understand  the  directions  before  installation.  Refer  to  impoant  safety 
information at the end of this document.
This  section  describes  installing  the  JuiceBox  Pro  onto  a  wall  mount.  If  installing  onto  a 
JuiceStand, refer to the JuiceStand Manual.
1.  Turn o the circuit breaker to the NEMA 14-50 outlet, NEMA 6-50 outlet, or hardwired 
electrical connection.
2.  Use a stud sensor to determine an appropriate mounting location, then use the 2 screws 
to secure the wall bracket.